1.
|
D. S. Armstrong et al. G0 Collaboration
Show Abstract
We have measured the beam-normal single-spin asymmetry in elastic scattering of transversely polarized 3 GeV electrons from unpolarized protons at Q2=0.15, 0.25 (GeV/c)2. The results are inconsistent with calculations solely using the elastic nucleon intermediate state and generally agree with calculations with significant inelastic hadronic intermediate state contributions. An provides a direct probe of the imaginary component of the 2γ exchange amplitude, the complete description of which is important in the interpretation of data from precision electron-scattering experiments.
Phys. Rev. Lett. 99, 092301 (2007)
Cited 2 times
|
|
2.
|
M. Poelker, J. Grames, J. Hansknecht, R. Kazimi, and J. Musson
Show Abstract
Even at a continuous wave facility such as CEBAF at Jefferson Lab, an electron beam with long time intervals (tens of ns) between individual bunches can be useful, for example, to isolate sources of background via time of flight detection or to measure the energy of neutral particles that cannot be separated with a magnetic field. This paper describes a demonstrated method to quickly and easily deliver bunches with repetition rates of 20 to 100 MHz corresponding to time intervals between 50 and 10 ns (respectively). This is accomplished by changing the ON/OFF frequency of the photogun drive laser by a small amount (Δf/f<20%), resulting in a bunch frequency equal to the beat frequency between the radio frequencies of the drive laser and the photoinjector chopper system.
Phys. Rev. ST Accel. Beams 10, 053502 (2007)
Cited 0 times
|
|
3.
|
C. K. Sinclair, P. A. Adderley, B. M. Dunham, J. C. Hansknecht, P. Hartmann, M. Poelker, J. S. Price, P. M. Rutt, W. J. Schneider, and M. Steigerwald
Show Abstract
Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory) require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2×105 C/cm2 and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.
Phys. Rev. ST Accel. Beams 10, 023501 (2007)
Cited 6 times
|
|
4.
|
A. Acha et al. HAPPEX Collaboration
Show Abstract
We report new measurements of the parity-violating asymmetry APV in elastic scattering of 3 GeV electrons off hydrogen and 4He targets with ⟨θlab⟩≈6.0°. The 4He result is APV=(+6.40±0.23(stat)±0.12(syst))×10-6. The hydrogen result is APV=(-1.58±0.12(stat)±0.04(syst))×10-6. These results significantly improve constraints on the electric and magnetic strange form factors GEs and GMs. We extract GEs=0.002±0.014±0.007 at ⟨Q2⟩=0.077 GeV2, and GEs+0.09GMs=0.007±0.011±0.006 at ⟨Q2⟩=0.109 GeV2, providing new limits on the role of strange quarks in the nucleon charge and magnetization distributions.
Phys. Rev. Lett. 98, 032301 (2007)
Cited 26 times
|
|
5.
|
J. Hansknecht and M. Poelker
Show Abstract
Light at 1560 nm from a gain-switched fiber-coupled diode laser and ErYb-doped fiber amplifier was frequency doubled to obtain over 2 W average power at 780 nm with ∼40 ps pulses and pulse repetition rate of 499 MHz. This light was used to drive the 100 kV DC high voltage GaAs photoemission gun at the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory to produce a high average current beam (100 μA) of highly spin-polarized electrons (>80%). This new drive-laser system represents a significant advance over laser systems used previously, providing significantly higher power and enhanced reliability.
Phys. Rev. ST Accel. Beams 9, 063501 (2006)
Cited 1 times
|
|
6.
|
K. A. Aniol et al. HAPPEX Collaboration
Show Abstract
We have measured the parity-violating electroweak asymmetry in the elastic scattering of polarized electrons from 4He at an average scattering angle ⟨θlab⟩=5.7° and a four-momentum transfer Q2=0.091 GeV2. From these data, for the first time, the strange electric form factor of the nucleon GEs can be isolated. The measured asymmetry of APV=(6.72±0.84(stat)±0.21(syst))×10-6 yields a value of GEs=-0.038±0.042(stat)±0.010(syst), consistent with zero.
Phys. Rev. Lett. 96, 022003 (2006)
Cited 35 times
|
|
7.
|
M. Baylac, P. Adderley, J. Brittian, J. Clark, T. Day, J. Grames, J. Hansknecht, M. Poelker, M. Stutzman, A. T. Wu, and A. S. Terekhov
Show Abstract
Strained-layer GaAs and strained-superlattice GaAs photocathodes are used at Jefferson Laboratory to create high average current beams of highly spin-polarized electrons. High electron yield, or quantum efficiency (QE), is obtained only when the photocathode surface is atomically clean. For years, exposure to atomic hydrogen or deuterium has been the photocathode cleaning technique employed at Jefferson Laboratory. This work demonstrates that atomic hydrogen cleaning is not necessary when precautions are taken to ensure that clean photocathode material from the vendor is not inadvertently dirtied while samples are prepared for installation inside photoemission guns. Moreover, this work demonstrates that QE and beam polarization can be significantly reduced when clean high-polarization photocathode material is exposed to atomic hydrogen from an rf dissociator-style atomic hydrogen source. Surface analysis provides some insight into the mechanisms that degrade QE and polarization due to atomic hydrogen cleaning.
Phys. Rev. ST Accel. Beams 8, 123501 (2005)
Cited 2 times
|
|
8.
|
D. S. Armstrong et al. G0 Collaboration
Show Abstract
We have measured parity-violating asymmetries in elastic electron-proton scattering over the range of momentum transfers 0.12≤Q2≤1.0 GeV2. These asymmetries, arising from interference of the electromagnetic and neutral weak interactions, are sensitive to strange-quark contributions to the currents of the proton. The measurements were made at Jefferson Laboratory using a toroidal spectrometer to detect the recoiling protons from a liquid hydrogen target. The results indicate nonzero, Q2 dependent, strange-quark contributions and provide new information beyond that obtained in previous experiments.
Phys. Rev. Lett. 95, 092001 (2005)
Cited 67 times
|
|
9.
|
J. M. Grames et al.
Show Abstract
Precision measurements of the relative analyzing powers of five electron beam polarimeters, based on Compton, Møller, and Mott scattering, have been performed using the CEBAF accelerator at the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory). A Wien filter in the 100 keV beam line of the injector was used to vary the electron spin orientation exiting the injector. High statistical precision measurements of the scattering asymmetry as a function of the spin orientation were made with each polarimeter. Since each polarimeter receives beam with the same magnitude of polarization, these asymmetry measurements permit a high statistical precision comparison of the relative analyzing powers of the five polarimeters. This is the first time a precise comparison of the analyzing powers of Compton, Møller, and Mott scattering polarimeters has been made. Statistically significant disagreements among the values of the beam polarization calculated from the asymmetry measurements made with each polarimeter reveal either errors in the values of the analyzing power or failure to correctly include all systematic effects. The measurements reported here represent a first step toward understanding the systematic effects of these electron polarimeters. Such studies are necessary to realize high absolute accuracy (ca. 1%) electron polarization measurements, as required for some parity violation measurements planned at Jefferson Laboratory. Finally, a comparison of the value of the spin orientation exiting the injector that provides maximum longitudinal polarization in each experimental hall leads to an independent and very precise (better than 10-4) absolute measurement of the final electron beam energy.
Phys. Rev. ST Accel. Beams 7, 042802 (2004)
Cited 4 times
|
|
10.
|
M. Poelker, K. P. Coulter, R. J. Holt, C. E. Jones, R. S. Kowalczyk, L. Young, B. Zeidman, and D. K. Toporkov
Show Abstract
The electron polarization of hydrogen (H) and deuterium (D) atoms in a spin-exchange optical-pumping apparatus has been measured as a function of H (D) density and magnetic-field strength. The atomic density was varied between 4×1013 and 2.6×1014 atoms/cm3 and the magnetic-field strength from 120 to 400 mT. The results suggest that the atoms approach spin-temperature equilibrium even though the magnetic fields are large compared to the critical fields of the atoms.
Phys. Rev. A 50, 2450 (1994)
Cited 6 times
|