|
1.
|
L. Cultrera, G. Gatti, P. Miglietta, F. Tazzioli, A. Perrone, J. T. Moody, and P. Musumeci
Show Abstract
Pulsed laser deposition (PLD) has been proposed several years ago as a suitable technique to deposit a pure Mg film over a radio frequency (rf) gun Cu backflange in order to obtain a high efficiency photocathode surface for the generation of high brightness electron beams. In this paper we report preliminary experimental results on the emission properties of a PLD grown Mg film within the high electric field gradients of a rf gun showing the effects of the rf conditioning process on the cathode surface. Even though a laser cleaning process should be performed on the sample surface in order to remove contaminated layers, the results presented here are very promising for the realization of a final Mg-based photocathode.
Phys. Rev. ST Accel. Beams 12, 043502 (2009)
Cited 0 times
|
|
2.
|
A. Cianchi et al.
Show Abstract
The new generation of linac injectors driving free electron lasers in the self-amplified stimulated emission (SASE-FEL) regime requires high brightness electron beams to generate radiation in the wavelength range from UV to x rays. The choice of the injector working point and its matching to the linac structure are the key factors to meet this requirement. An emittance compensation scheme presently applied in several photoinjectors worldwide is known as the “Ferrario” working point. In spite of its great importance there was, so far, no direct measurement of the beam parameters, such as emittance, transverse envelope, and energy spread, in the region downstream the rf gun and the solenoid of a photoinjector to validate the effectiveness of this approach. In order to fully characterize the beam dynamics with this scheme, an innovative beam diagnostic device, the emittance meter, consisting of a movable emittance measurement system, has been designed and built. With the emittance meter, measurements of the main beam parameters in both transverse phase spaces can be performed in a wide range of positions downstream the photoinjector. These measurements help in tuning the injector to optimize the working point and provide an important benchmark for the validation of simulation codes. We report the results of these measurements in the SPARC photoinjector and, in particular, the first experimental evidence of the double minimum in the emittance oscillation, which provides the optimized matching to the SPARC linac.
Phys. Rev. ST Accel. Beams 11, 032801 (2008)
Cited 5 times
|
|
3.
|
M. Ferrario et al.
Show Abstract
In this Letter we report the first experimental observation of the double emittance minimum effect in the beam dynamics of high-brightness electron beam generation by photoinjectors; this effect, as predicted by the theory, is crucial in achieving minimum emittance in photoinjectors aiming at producing electron beams for short wavelength single-pass free electron lasers. The experiment described in this Letter was performed at the SPARC photoinjector site, during the first stage of commissioning of the SPARC project. The experiment was made possible by a newly conceived device, called an emittance meter, which allows a detailed and unprecedented study of the emittance compensation process as the beam propagates along the beam pipe.
Phys. Rev. Lett. 99, 234801 (2007)
Cited 3 times
|
|
4.
|
L. Cultrera, M. I. Zeifman, and A. Perrone
Show Abstract
The formation of a columnar structure, different expansion directions of the luminous (monomers) and obscure (droplets) plume species, and gradual deflection of the luminous plume are found to be interrelated in special experiments on pulsed laser deposition of Si. The obscure species always expands in the direction of incidence, which leads to a characteristic skewed angular distribution of the deposition rate. These observations are explained by the change of the microscopic mechanism of laser ablation from monomer evaporation at low local fluences to phase explosion at higher local fluences.
Phys. Rev. B 73, 075304 (2006)
Cited 3 times
|