Phys. Rev. ST Accel. Beams 6, 073501 (2003) [6 pages]Operation of an electron-cyclotron-resonance ion source with supplemental electron injection
Experimental observations obtained on an electron-cyclotron-resonance ion source with electron injection by a ferroelectric cathode are presented. The results are in reasonable agreement with the proposed qualitative plasma model based on the Fokker-Planck equation. A procedure for the optimized operation of an ion source with electron injection is presented on the base of the experimental observations. This article is available under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. © 2003 The American Physical Society URL:
http://link.aps.org/doi/10.1103/PhysRevSTAB.6.073501
DOI:
10.1103/PhysRevSTAB.6.073501
PACS:
52.50.Gj, 52.65.Ff, 79.75.+g, 77.80.–e
|