Phys. Rev. ST Accel. Beams 5, 124401 (2002) [8 pages]

Electron cloud measurements and simulations for the Brookhaven Relativistic Heavy Ion Collider

Download: PDF (412 kB) or gzip'ed PS (611 kB) Export: BibTeX or EndNote (RIS)

W. Fischer, J. M. Brennan, M. Blaskiewicz, and T. Satogata
Brookhaven National Laboratory, Upton, New York 11973

Received 3 September 2002; published 5 December 2002

Intense ion beams in the Brookhaven Relativistic Ion Collider lead to a rise in the vacuum pressure. Electron clouds can contribute to such a process. To measure electron cloud densities the coherent tune shift along the bunch train was observed with different bunch spacings and intensities. From the measured coherent tune shifts, electron cloud densities are computed and compared with densities obtained in electron cloud simulations.


©2002 The American Physical Society

URL: http://link.aps.org/abstract/PRSTAB/v5/e124401
DOI: 10.1103/PhysRevSTAB.5.124401
PACS: 29.27.Bd