Phys. Rev. ST Accel. Beams 4, 074201 (2001) [6 pages]

Design and performance simulations of the bunch compressor for the Advanced Photon Source Low-Energy Undulator Test Line free-electron laser

Download: PDF (211 kB) Export: BibTeX or EndNote (RIS)

M. Borland
ANL, Argonne, Illinois 60439

Received 11 October 2000; published 13 July 2001

A magnetic bunch compressor was designed and commissioned to provide higher peak current for the Advanced Photon Source's Low-Energy Undulator Test Line free-electron laser [S. V. Milton et al., Phys. Rev. Lett. 85, 988 (2000)]. Of great concern is limiting emittance growth due to coherent synchrotron radiation. Tolerances must also be carefully evaluated to find stable operating conditions and ensure that the system can meet operational goals. Automated matching and tolerance simulations allowed consideration of numerous configurations, pinpointing those with reduced error sensitivity. Simulations indicate significant emittance growth up to 600 A peak current, for which the normalized emittance will increase from 5 to about 8.5μm. The simulations also provide predictions of emittance variation with chicane parameters and precompressor linac phase, which we hope to verify experimentally.