Phys. Rev. ST Accel. Beams 4, 072801 (2001) [8 pages]

Oscilloscope measurement of the synchronous phase shift in an electron storage ring

Abstract
No Citing Articles
Download: PDF (143 kB) or gzip'ed PS (135 kB) Export: BibTeX or EndNote (RIS)

R. H. A. Farias, Liu Lin, A. R. D. Rodrigues, and P. F. Tavares
LNLS, Laboratório Nacional de Luz Síncrotron, Cx. Postal 6192, CEP 13083-970, Campinas, Brazil

A. Hofmann
CERN-SL Division, Geneva, Switzerland

Received 5 March 2001; published 12 July 2001

We present a new technique to measure the synchronous phase shift in an electron storage ring. A digital sampling oscilloscope is used to observe the cavity and beam signals simultaneously, and the amplitude and relative phase are obtained from a Fourier transform of the time-domain data. This procedure gives 6 mdeg resolution and is largely insensitive to input signal amplitude variations. The measurement system was used to study the dependence of the synchronous phase shift on beam current, gap voltage, and beam energy in the Brazilian Synchrotron Light Source electron storage ring.


©2001 The American Physical Society

URL: http://link.aps.org/abstract/PRSTAB/v4/e072801
DOI: 10.1103/PhysRevSTAB.4.072801
PACS: 29.20.-c

[ Abstract  |  Previous article  |  Next article  |  Issue 7 ]