corner
corner

Phys. Rev. ST Accel. Beams 3, 092001 (2000) [25 pages]

Superconducting TESLA cavities

Download: PDF (1,261 kB) Export: BibTeX or EndNote (RIS)

B. Aune et al.
Show All Authors/Affiliations

Received 19 April 2000; published 22 September 2000

The conceptional design of the proposed linear electron-positron collider TESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with an accelerating gradient of Eacc≥25MV/m at a quality factor Q0≥5×109. The design goal for the cavities of the TESLA Test Facility (TTF) linac was set to the more moderate value of Eacc≥15MV/m. In a first series of 27 industrially produced TTF cavities the average gradient at Q0 = 5×109 was measured to be 20.1±6.2MV/m, excluding a few cavities suffering from serious fabrication or material defects. In the second production of 24 TTF cavities, additional quality control measures were introduced, in particular, an eddy-current scan to eliminate niobium sheets with foreign material inclusions and stringent prescriptions for carrying out the electron-beam welds. The average gradient of these cavities at Q0 = 5×109 amounts to 25.0±3.2MV/m with the exception of one cavity suffering from a weld defect. Hence only a moderate improvement in production and preparation techniques will be needed to meet the ambitious TESLA goal with an adequate safety margin. In this paper we present a detailed description of the design, fabrication, and preparation of the TESLA Test Facility cavities and their associated components and report on cavity performance in test cryostats and with electron beam in the TTF linac. The ongoing research and development towards higher gradients is briefly addressed.

This article is available under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI.

© 2000 The American Physical Society

URL:
http://link.aps.org/doi/10.1103/PhysRevSTAB.3.092001
DOI:
10.1103/PhysRevSTAB.3.092001
PACS:
84.40.-x, 41.20.-q, 41.75.Ht, 74.60.-w