Phys. Rev. ST Accel. Beams 3, 034401 (2000) [19 pages]

Single bunch longitudinal measurements at the Cornell Electron-Positron Storage Ring

Download: PDF (2015 kB) or gzip'ed PS (1999 kB) Export: BibTeX or EndNote (RIS)

R. Holtzapple, M. Billing, D. Hartill, and M. Stedinger
Laboratory of Nuclear Studies, Cornell University, Ithaca, New York 14853

B. Podobedov
Stanford Linear Accelerator Center, Stanford University, Stanford, California 94309

Received 4 March 1999; published 13 March 2000

Measurements of the beam's bunch length in the Cornell Electron-Positron Storage Ring (CESR) have been made using a streak camera. The streak camera uses visible synchrotron radiation produced by the beam to measure its longitudinal distribution. A description of CESR, the experimental setup, the streak camera used, and systematic errors and analysis techniques of the streak camera are described in this paper. The dependence of the bunch distribution on the current and accelerating rf voltage for a single bunch CESR was measured and compared with a theoretical model of CESR. The CESR vacuum chamber impedance is determined from the measured bunch distributions and is presented in this paper.


©2000 The American Physical Society

URL: http://link.aps.org/doi/10.1103/PhysRevSTAB.3.034401
DOI: 10.1103/PhysRevSTAB.3.034401
PACS: 29.27.Bd