Phys. Rev. ST Accel. Beams 3, 112001 (2000) [6 pages]Cavity longitudinal loss factor measurement by means of a beam test facility
A. Palmieri and L. Tecchio
G. V. Lamanna and V. Variale
A. V. Aleksandrov and P. V. Logatchov
V. G. Vaccaro
M. R. Masullo Received 20 June 2000; published 20 November 2000 A new method for the measurement of loss factor for an rf cavity is presented. The method consists of measuring the above quantity by means of the detection of both the rf voltage induced by an electron bunch in the device under test and the bunch charge. The device to be investigated is a copper reentrant T-shaped cavity. The experimental results and their comparison with analytical and numerical results are presented. ©2000 The American Physical Society
URL: http://link.aps.org/doi/10.1103/PhysRevSTAB.3.112001 [ Abstract | Previous article | Next article | Issue 11 ] |