Phys. Rev. ST Accel. Beams 12, 091002 (2009) [5 pages]Measurement of chromatic X-Y coupling
We have measured and corrected chromatic X-Y coupling at an interaction point to improve the luminosity of KEKB. We have measured the beam position of betatron oscillations induced by the kicker using turn-by-turn beam position monitors. A phase space structure reconstructed by the beam position provides us not only the Twiss parameters but also information regarding X-Y coupling. We have also determined chromatic X-Y coupling using the measured X-Y coupling at each momentum deviation from the designed beam energy. Skew sextupole magnets are used to correct the chromatic X-Y coupling. This article is available under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. © 2009 The American Physical Society URL:
http://link.aps.org/doi/10.1103/PhysRevSTAB.12.091002
DOI:
10.1103/PhysRevSTAB.12.091002
PACS:
29.20.db
|
