Phys. Rev. ST Accel. Beams 12, 102802 (2009) [7 pages]Investigation of the vertical instability at the Argonne Intense Pulsed Neutron Source
The rapid cycling synchrotron of the intense pulsed neutron source at Argonne National Laboratory normally operates at an average beam current of 14 to 15 μA, accelerating protons from 50 to 450 MeV 30 times per second. The beam current is limited by a single-bunch vertical instability that occurs in the later part of the 14 ms acceleration cycle. By analyzing turn-by-turn beam position monitor data, two cases of vertical beam centroid oscillations were discovered. The oscillations start from the tail of the bunch, build up, and develop toward the head of the bunch. The development stops near the bunch center and oscillations remain localized in the tail for a relatively long time (2–4 ms, 1–2×104 turns). This vertical instability is identified as the cause of the beam loss. We compared this instability with a head-tail instability that was purposely induced by switching off sextupole magnets. It appears that the observed vertical instability is different from the classical head-tail instability. This article is available under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. © 2009 The American Physical Society URL:
http://link.aps.org/doi/10.1103/PhysRevSTAB.12.102802
DOI:
10.1103/PhysRevSTAB.12.102802
PACS:
29.27.Bd, 29.20.dk, 41.75.Ak, 41.85.Qg
|