Phys. Rev. ST Accel. Beams 11, 104002 (2008) [6 pages]Correction of multiple nonlinear resonances in storage rings
The correct implementation of the nonlinear lattice model is crucial to achieving the design performance in storage rings. We describe here a method for the simultaneous correction of multiple nonlinear resonances based on local resonance measurements and numerical fits of the sextupole components. This method has been applied for the simultaneous correction of two sextupole resonances excited in the Diamond storage ring. The local correction of these resonances has been achieved with unprecedented precision. We also point out that this method has the potential to lead to an effective reconstruction of the local sextupole component errors around the whole ring circumference. This article is available under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. © 2008 The American Physical Society URL:
http://link.aps.org/doi/10.1103/PhysRevSTAB.11.104002
DOI:
10.1103/PhysRevSTAB.11.104002
PACS:
05.45.−a, 29.20.db
|